Home    |    AMAX Products    |    Technical Information    |    Testimonials    |    AMAX Presentations    |    Contact Us

 
 
TECHNICAL INFORMATION

Project-specific engineering support is available and included.  Please contact us with your requirements.  We will also provide anticipated cooling output based on climate geography, efficiency and project cost payback and savings calculations.

> Download the AMAX Specifications.

>
Download the AMAX Binder.

>
Download the AMAX Flyer.

>
Download the AMAX Economizer Brochure.

>
Download the AMAX Economizer Data Sheet.
 

 
 
 
 How AMAX Works

Base Model

Base model using Indirect/Direct (IDEC) evaporative cooling only.

The AMAX� design uses an integrated �cooling tower� to chill water to near the ambient wet bulb temperature. This chilled water is then pumped through the indirect coil to pre-cool fresh outdoor air. This air then passes through direct evaporative media to supply air to the conditioned space at a temperature below the ambient wet bulb. This design offers a simple and robust system that uses a constant water circuit to transfer heat from the supply air stream to the exhaust air stream through evaporative cooling. The basic AMAX� design can be customized to supply Indirect Evaporative Cooled air (IEC) without added humidity. Additional cooling can be achieved through integrated chilled water coils or a full integrated compressor circuit.

AMAX is also offered in the Powered Economiser� configuration. Powered Economisers� are an inexpensive supplement to Direct Expansion (DX) cooling systems and use the blower fan in the DX system to supply pre-cooled air. Powered Economisers� can be used to extend the �free cooling season� in when outdoor air will satisfy cooling requirements. Or this equipment can be used as a pre-cooler for condensers to extend DX equipment life, minimize energy consumption and reduce DX equipment size and installed cost.

Please contact our engineering staff for energy and savings calculations and potential rebates.
 

 

 

 

 

 

 

 

 

 

 

 

 
 
 
 Indirect/Direct (IDEC)

Maximizes energy saving potential of evaporative process

 

 

 

 

 

 

1. Dust Filter

2. Indirect Cooling Coil

3. Cooling Media

4. Drop Stop Media

5. Secondary Fan

6. Blower Assembly

7. Motor

 
 
 
 Hybrid

Indirect effectiveness is boosted by compressor chilled water.

 

 

 

 

 

 

1. Dust Filter

2. Indirect Cooling Coil

3. Chilled Water Coil

4. Cooling Media

5. Drop Stop Media

6. Secondary Fan

7. Blower Assembly

8. Motor

 

 
 
 
 Hybrid DX

Full Comfort in wide variety of geographies and climates.

 

 

 

 

 

 

1. Dust Filter

2. Indirect Cooling Coil

3. Chilled Water Coil

4. Cooling Media

5. Drop Stop Media

6. Secondary Fan

7. Blower Assembly

8. Motor

 

 
 
 
   
          
    
 


    
 